🚚 Nationwide Delivery on Industrial Products
🏭 Industrial Sensors & Automation Equipment Available
🌡️ High-Accuracy Monitoring & Detection Devices
⚡ Reliable Actuators & Smart Control Systems
EMCT EMCT EMCT

(04) 551 2125

Mon-Sat 9:00 am-5:00 pm

  sales@emcglobaltrade.com

Customer Support 24/7

0 0.0 AED 0
0 Shopping Cart

No products in the cart.

Return To Shop
Shopping cart (0)
Subtotal: 0.0 AED

Checkout

Sign in
My Account
Login Register

Lost password?

A password will be sent to your email address.

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy.

  • Home
  • Shop
  • News
  • About Us
  • Contact Us
  • Categories
    • Fluxera
      • Air Velocity/Volume/Flow (Switches & Transmitters)
      • CO2/CO/PM2.5/VOC/CH2O/ Combustion/Toxic Gases
      • Damper Actuators
        • Failsafe Damper Actuators
        • Modulating Damper Actuators
        • On/Off Damper Actuators
      • Flow & Heat Meters
      • Occupancy Sensor/Level/Ambient Light Sensor/Water Leak
      • Pressure/Differential Pressure (Switches & Transmitters)
      • Temperature (Sensors & Transmitters)
      • Temperature/Humidity (Sensors & Transmitters)
      • Temperature/Humidity/Differential Pressure Display Unit
    • Johnson Controls
      • Refrigeration Controls
        • Dual Press Control
        • Evaporator Temperature Control
        • Oil Diff. Press. Control
        • Pressure Control
    • ELBI
      • Expansion Tanks/Air Separators
        • Air Separators
        • ELBI’s Hot Water Cylinder and storage tank
        • Fixed bladder expansion tanks for heating (35 – 500 litres)   
        • Replacable bladder expansion tanks for heating (500 – 2000 litres)   
Menu Categories
  • Home
  • Shop
  • News
  • About Us
  • Contact Us
  • Fluxera
    • Temperature/Humidity/Differential Pressure Display Unit
    • Flow & Heat Meters
    • Globe Valve
    • Globe Valve Actuator
    • Butterfly Valve
    • Butterfly Valve Actuator
      • BFVAH High-Performance Butterfly Valve Actuator
    • Air Velocity/Volume/Flow (Switches & Transmitters)
    • CO2/CO/PM2.5/VOC/CH2O/ Combustion/Toxic Gases
    • Damper Actuators
      • Modulating Damper Actuators
      • Failsafe Damper Actuators
      • On/Off Damper Actuators
    • Occupancy Sensor/Level/Ambient Light Sensor/Water Leak
    • Temperature (Sensors & Transmitters)
    • Temperature/Humidity (Sensors & Transmitters)
    • Pressure/Differential Pressure (Switches & Transmitters)
  • Johnson Controls
    • Refrigeration Controls
      • Oil Diff. Press. Control
      • Dual Press Control
      • Evaporator Temperature Control
      • Pressure Control
  • ELBI
    • Expansion Tanks/Air Separators
      • Air Separators
      • ELBI’s Hot Water Cylinder and storage tank
      • Fixed bladder expansion tanks for heating (35 - 500 litres)   
      • Replacable bladder expansion tanks for heating (500 - 2000 litres)   
Sign in
Wishlist Please, enable Wishlist.
EMCT EMCT EMCT
0 0.0 AED 0
0 Shopping Cart

No products in the cart.

Return To Shop
Shopping cart (0)
Subtotal: 0.0 AED

Checkout

Home Shop Fluxera Page 5

Page 5

Return to previous page
Grid
List
Show

10 in stock

DA20 Damper Actuator, 20Nm Series
Quick View

DA40S101 / Fail-safe Damper Act, Mod, 40Nm, 0-10V, Run Time 75sec, Failsafe Rtn 32sec, 28V AC/DC, 2 Aux Sw

825.0 AED VAT

Specifications:

  • Torque: 40 Nm
  • Damper size: ≤8 m2(see details in the manual)
  • Direction of rotation: Set by knob
  • Position indicator: Mechanical
  • Manual override: Set by push button
  • Angle of rotation: Max. 95°
  • Running time: Standard 150s, medium speed 75s optional
  • Connected shaft: Circular Φ12~26.7mm, square 12~18mm, min. length 50mm
  • Model:SW1A(1xSPDT,0.5A/250VAC);SW2A(2xSPDT,0.5A/250VAC)
  • Work temp.: -30~50°C, 0~95%RH, no cond. (EN60730-1)
  • Storage temp.: -40~80°C
  • Power Protection: Class II-totally insulated
  • Enclosure Protection: IP54
  • Weight: 0.13kg
Add to cart

10 in stock

DPTL310 / Air Diff. Press. Transmitter, 0-250 Pa, Output  0–5 V, 0–10 V, or 4–20 mA
Quick View

DPTL310 / Air Diff. Press. Transmitter, 0-250 Pa, Output 0–5 V, 0–10 V, or 4–20 mA

250.0 AED VAT

Specifications:

  • Medium: non-combustible, non-corrosive air, insensitive to moisture, dust, condensation and oil
  • Working Temp.: -20~70°C
  • Medium Temp.: 0~60°C
  • Temp. Compensation: 0~50°C
  • Range: 25Pa(±12.5Pa) ~10kPa(±5kPa)
  • Accuracy: ±1.0%FS (±2.0%FS@25Pa range)
  • Long term stability: ±0.5%FS/Year
  • Thermal effect: <0.05%FS/°C (zero), <0.08%FS/°C (FS)
  • Response Time: 0.5/1/2/5s, can be set by DIP switches
  • Zero set: easy to reset by external key
  • Process Connection: 5mm ID tubing
  • Display: 5 digits LCD, size 44x18mm, with unit indication
  • Units: 5 units, selected by DIP switches
  • Output: 0~5V/0~10V/4~20mA(2 or 3 wires), RS485/Modbus
  • Output Load: ≤500Ω (current), ≥2kΩ (voltage)
  • Power: Voltage: 16~28VAC/ 16~35VDC
  • Current: 18.5~35VDC (RL=500Ω); 8.5~35VDC (RL=0Ω)
  • Housing: PC, fire retardant UL94V-0
  • Protection: IP65
  • Weight: 180g
  • Approval: CE
  • Accessories: flush mount panel (model DPTL-A), can be ordered separately
Add to cart

10 in stock

DPTL Differential Pressure Transmitter
Quick View

DPTL311 / Air Diff. Press. Transmitter, 0-250 Pa, Output 0–5 V, 0–10 V, or 4–20 mA, LCD

313.0 AED VAT

Specifications:

  • Medium: non-combustible, non-corrosive air, insensitive to moisture, dust, condensation and oil
  • Working Temp.: -20~70°C
  • Medium Temp.: 0~60°C
  • Temp. Compensation: 0~50°C
  • Range: 25Pa(±12.5Pa) ~10kPa(±5kPa)
  • Accuracy: ±1.0%FS (±2.0%FS@25Pa range)
  • Long term stability: ±0.5%FS/Year
  • Thermal effect: <0.05%FS/°C (zero), <0.08%FS/°C (FS)
  • Response Time: 0.5/1/2/5s, can be set by DIP switches
  • Zero set: easy to reset by external key
  • Process Connection: 5mm ID tubing
  • Display: 5 digits LCD, size 44x18mm, with unit indication
  • Units: 5 units, selected by DIP switches
  • Output: 0~5V/0~10V/4~20mA(2 or 3 wires), RS485/Modbus
  • Output Load: ≤500Ω (current), ≥2kΩ (voltage)
  • Power: Voltage: 16~28VAC/ 16~35VDC
  • Current: 18.5~35VDC (RL=500Ω); 8.5~35VDC (RL=0Ω)
  • Housing: PC, fire retardant UL94V-0
  • Protection: IP65
  • Weight: 180g
  • Approval: CE
  • Accessories: flush mount panel (model DPTL-A), can be ordered separately
Add to cart

10 in stock

DPTL610 / Air Diff. Press. Transmitter, 0-2500 Pa, Output  0–5 V, 0–10 V, or 4–20 mA
Quick View

DPTL610 / Air Diff. Press. Transmitter, 0-2500 Pa, Output 0–5 V, 0–10 V, or 4–20 mA

250.0 AED VAT

Specifications:

  • Medium: non-combustible, non-corrosive air, insensitive to moisture, dust, condensation and oil
  • Working Temp.: -20~70°C
  • Medium Temp.: 0~60°C
  • Temp. Compensation: 0~50°C
  • Range: 25Pa(±12.5Pa) ~10kPa(±5kPa)
  • Accuracy: ±1.0%FS (±2.0%FS@25Pa range)
  • Long term stability: ±0.5%FS/Year
  • Thermal effect: <0.05%FS/°C (zero), <0.08%FS/°C (FS)
  • Response Time: 0.5/1/2/5s, can be set by DIP switches
  • Zero set: easy to reset by external key
  • Process Connection: 5mm ID tubing
  • Display: 5 digits LCD, size 44x18mm, with unit indication
  • Units: 5 units, selected by DIP switches
  • Output: 0~5V/0~10V/4~20mA(2 or 3 wires), RS485/Modbus
  • Output Load: ≤500Ω (current), ≥2kΩ (voltage)
  • Power: Voltage: 16~28VAC/ 16~35VDC
  • Current: 18.5~35VDC (RL=500Ω); 8.5~35VDC (RL=0Ω)
  • Housing: PC, fire retardant UL94V-0
  • Protection: IP65
  • Weight: 180g
  • Approval: CE
  • Accessories: flush mount panel (model DPTL-A), can be ordered separately
Add to cart

10 in stock

DPTL Differential Pressure Transmitter
Quick View

DPTL611 / Air Diff. Press. Transmitter, 0-2500 Pa, Output 0–5 V, 0–10 V, or 4–20 mA, LCD

313.0 AED VAT

Specifications:

  • Medium: non-combustible, non-corrosive air, insensitive to moisture, dust, condensation and oil
  • Working Temp.: -20~70°C
  • Medium Temp.: 0~60°C
  • Temp. Compensation: 0~50°C
  • Range: 25Pa(±12.5Pa) ~10kPa(±5kPa)
  • Accuracy: ±1.0%FS (±2.0%FS@25Pa range)
  • Long term stability: ±0.5%FS/Year
  • Thermal effect: <0.05%FS/°C (zero), <0.08%FS/°C (FS)
  • Response Time: 0.5/1/2/5s, can be set by DIP switches
  • Zero set: easy to reset by external key
  • Process Connection: 5mm ID tubing
  • Display: 5 digits LCD, size 44x18mm, with unit indication
  • Units: 5 units, selected by DIP switches
  • Output: 0~5V/0~10V/4~20mA(2 or 3 wires), RS485/Modbus
  • Output Load: ≤500Ω (current), ≥2kΩ (voltage)
  • Power: Voltage: 16~28VAC/ 16~35VDC
  • Current: 18.5~35VDC (RL=500Ω); 8.5~35VDC (RL=0Ω)
  • Housing: PC, fire retardant UL94V-0
  • Protection: IP65
  • Weight: 180g
  • Approval: CE
  • Accessories: flush mount panel (model DPTL-A), can be ordered separately
Add to cart
ELECTROMAGNETIC FLOW METER
Quick View

ELECTROMAGNETIC FLOW METER

Specifications

Mechanical Data:

  • Materials: Electrode: 316L (Stainless Steel), Hastelloy, Titanium, Tantalum, etc. Liner: PTFE, Soft Rubber, Hard Rubber. Measuring tube: SUS 304  Body & Flange: Carbon Steel. Ground Ring: 316L (stainless steel), HC, Ti, Ta, Cu.
  • Connection of Flange: National Standard GB9119-88 (DIN2051, BS4504), JIS, ANSI. Screw. Insertion type, Tri-clamp for sanitary application.
  • Ambient Environment: Temperature: -Sensor: -40 to 80°C; Transducer: -15 to 50°C. Humidity: ≤85% (RH) at 20°C.
  • Measurable Fluid: Water
  • Fluid Temperature: -20°C~80°C, 80°C~130°C, 130°C~180°C Depending on Lining Material
  • Pressure: 10Bar, 16Bar Standard, 40Bar
  • Flow Velocity: Limit of Span 0.5~10m/s, 1~5m/s Recommended
  • Accuracy: 3% (Option), 0.5%, 1.0% of F.S.
  • Protection Ratings: Integral Type: IP65. Remote Type: Sensor IP68, Transducer IP65.
  • Ex-Proof Protection: Exde ib ii BT2
Electrical Data:
  • Power Supply: 220VAC ±10%, 50-60Hz, 24VDC ±10%. Battery power (3-5years)
  • Power Consumption: ≤8W
  • Output Signals: 4~20m ADC, Load ≤ 750ohm$, 0~3kHz, 5V with Source and Changeable Width. High terminal and Effective Frequency Output Voltage Output: 0-5 V DC
  • Communication Interface: RS232, RS485, HART
  • Display Unit: Flow rate (4-digits), Totalizer (9-digits), Velocity, Alarm status. Scale unit: selectable of L/h, L/m, L/s, m3/h, m3/m, m3/s .Flow direction: selectable by program. 3 Digits display below of decimal points. K-factor: 5 digits. Mounting: Integral type; Remote Type
  • Data Storage: Data Logger for 2-3years.

Approval:

  • Compliance:  ISO9001-2008, CE, EMC Directive 2014/30/EU
Read more

10 in stock

G3Ex310 / Ex-proof CH4 Gas Detector, 0-100% LEL, 0-10Vdc, IP66
Quick View

G3Ex310 / Ex-proof CH4 Gas Detector, 0-100% LEL, 0-10Vdc, IP66

989.0 AED VAT

Specifications:

  • Gases and specifications: see the table below
  • Power: 18~30VDC
  • Output: 0~10V, 4~20mA (3 wires), RS485/Modbus
  • Relay: SPST, 3A/30VDC
  • Load: ≥2kΩ (0-10V), ≤500Ω (4-20mA)
  • Display: LED digital display, power/fault/alarm LED indicator
  • Operating condition: combustible gas -40~70°C, toxic gas -20~55°C, 10~95%RH(Non-cond.), pressure 86~106kPa
  • Housing: die cast aluminum housing, SS probe and SS sintered mesh filter
  • Agency Approvals: Ex d ⅡC T6 Gb, ATEX (2014/34/EU), EMC (2014/30/EU, EN50270), CMC Metrological Certificate
  • Weight: 1.4kg
  • Explosion proof audible & visual alarm: model ASG24VDC, sound intensity>=90dB@0.1m, light intensity 1800~2400mcd, to be ordered separately
  • Intrinsically safe infrared remote controller: model FYF3, for field programming, to be ordered separately
  • General infrared remote controller: model YK-0, for safe zone programming, to be ordered separately
  • Models
  • Protection: IP66
Add to cart
GVA06 Globe Valve Actuator
Quick View

GVA06 Globe Valve Actuator, 600N Series

 

Pre-order via Add to Quote       

 

Specifications

 
  • Force: 600N
  • Stroke: 20mm, self-adaptive range 10~25mm
  • Medium and temp.: Water or steam, -10~200°C
  • Working temp.: -20~50°C, 0~95%RH, no cond.(EN60730-1)
  • Storage temp.: -40~80°C
  • Direction of operation: DIP switchable
  • Position indicator: Mechanical
  • Manual operation: By two push buttons
  • Running time: Standard 60s(3s/mm) or medium speed 40s(2s/mm), DIP switchable
Read more
GVA06 Globe Valve Actuator
Quick View

GVA10 Globe Valve Actuator, 1000N Series

 

Pre-order via Add to Quote       

 

Specifications

 
  • Force: 1000N
  • Stroke: 20mm, self-adaptive range 15~25mm
  • Medium and temp.: Water or steam, -10~200°C
  • Working temp.: -20~50°C, 0~95%RH, no cond. (EN60730-1)
  • Storage temp.: -40~80°C
  • Direction of operation: DIP switchable
  • Position indicator: Mechanical
  • Manual operation: By two push buttons
  • Running time: Standard 60s(3s/mm) or medium speed 40s(2s/mm), DIP switchable
Read more
GVA06 Globe Valve Actuator
Quick View

GVA20 Globe Valve Actuator, 2000N Series

 

Pre-order via Add to Quote       

 

Specifications

 
  • Force: 2000N
  • Stroke: 20 or 40mm, self-adaptive range 15~30 or 35~50mm
  • Medium and temp.: Water or steam, -10~200°C
  • Working temp.: -20~50°C, 0~95%RH, no cond. (EN60730-1)
  • Storage temp.: -40~80°C
  • Direction of operation: DIP switchable
  • Position indicator: Mechanical
  • Manual operation: By two push buttons
  • Running time: DIP switchable
20mm: Standard 60s(3s/mm) or medium speed 40s(2s/mm) 40mm: Standard 120s(3s/mm) or medium speed 80s(2s/mm)  
Read more
GVA06 Globe Valve Actuator
Quick View

GVA35 Globe Valve Actuator, 3500N Series

 

Pre-order via Add to Quote       

 

Specifications

 
  • Force: 3500N
  • Stroke: 40mm, self-adaptive range 35~50mm
  • Medium temp.: -10~200°C
  • Working temp.: -20~70°C, 0~95%RH, no cond. (EN60730-1)
  • Storage temp.: -40~80°C
  • Direction of operation: DIP switchable
  • Position indicator: Mechanical
  • Manual operation: By two push buttons
  • Running time: Standard 120s(3s/mm) or medium speed 80s(2s/mm), DIP switchable
  • Driver: Brushless DC motor (BLDC)
Read more
GVF Globe Valve, Three way
Quick View

GVF Globe Valve, Three way

 

Pre-order via Add to Quote

 

Specifications

  • Size: DN15~250
  • Pressure: PN16
  • Medium: Cool, hot water, 50% or lower glycol water
  • Medium temperature: -10~120°C
  • Valve type: Three-way
  • Strike: 10~40mm, see Models
  • Flow characteristics: A-AB: equal percentage; B-AB: linear
  • Regulating ratio: DN15~50: 50: 1; DN65~250: 100: 1
  • Leakage rate: A-AB: ≤0.01% Kvs (DN15~DN150), ≤0.02% Kvs(DN200~DN250); B-AB: 0.5%~2%Kvs; no leak on stem
  • Pipe connection: Flange, comply with ISO7005, HG20592
  • Action direction: A-AB close when stem goes up
  • Install direction: Valve stem upward or horizontal
Read more
  • prev
  • 1
  • …
  • 4
  • 5
  • 6
  • …
  • 9
  • next

Product Categories

  • ELBI
  • Fluxera
    • Air Velocity/Volume/Flow (Switches & Transmitters)
    • Butterfly Valve
    • Butterfly Valve Actuator
    • CO2/CO/PM2.5/VOC/CH2O/ Combustion/Toxic Gases
    • Damper Actuators
    • Flow & Heat Meters
    • Globe Valve
    • Globe Valve Actuator
    • Occupancy Sensor/Level/Ambient Light Sensor/Water Leak
    • Pressure/Differential Pressure (Switches & Transmitters)
    • Temperature (Sensors & Transmitters)
    • Temperature/Humidity (Sensors & Transmitters)
    • Temperature/Humidity/Differential Pressure Display Unit
  • Johnson Controls

Filter by price

Price: —

Controls & Instruments

YOU NEED

EMCT Global Trading LLC is a leading HVAC contractor and technical service provider.

SHOP NOW

Office 44, 6th Floor, Mai Tower, Al-Nahda 1, Dubai-UAE

Contact@emcglobaltrade.com
 (04) 551 2125

THE COMPANY

About Us
Contact Us
Terms & Conditions
News

IMPORTANT LINKS

Privacy Policy
Shipping Policy
Price & Payment
Refund Policy

OTHERS

Map & Location

Connect With Us

Facebook Instagram Linkedin

Copyright © 2026 E-Solutions

Home
Shop
Wishlist
More
More
  • Home
  • Shop
  • News
  • About Us
  • Contact Us
  • Categories
    • Fluxera
      • Air Velocity/Volume/Flow (Switches & Transmitters)
      • CO2/CO/PM2.5/VOC/CH2O/ Combustion/Toxic Gases
      • Damper Actuators
        • Failsafe Damper Actuators
        • Modulating Damper Actuators
        • On/Off Damper Actuators
      • Flow & Heat Meters
      • Occupancy Sensor/Level/Ambient Light Sensor/Water Leak
      • Pressure/Differential Pressure (Switches & Transmitters)
      • Temperature (Sensors & Transmitters)
      • Temperature/Humidity (Sensors & Transmitters)
      • Temperature/Humidity/Differential Pressure Display Unit
    • Johnson Controls
      • Refrigeration Controls
        • Dual Press Control
        • Evaporator Temperature Control
        • Oil Diff. Press. Control
        • Pressure Control
    • ELBI
      • Expansion Tanks/Air Separators
        • Air Separators
        • ELBI’s Hot Water Cylinder and storage tank
        • Fixed bladder expansion tanks for heating (35 – 500 litres)   
        • Replacable bladder expansion tanks for heating (500 – 2000 litres)   

Powered by
Necessary cookies enable essential site features like secure log-ins and consent preference adjustments. They do not store personal data.
None
Functional cookies support features like content sharing on social media, collecting feedback, and enabling third-party tools.
None
Analytical cookies track visitor interactions, providing insights on metrics like visitor count, bounce rate, and traffic sources.
None
Advertisement cookies deliver personalized ads based on your previous visits and analyze the effectiveness of ad campaigns.
None
Unclassified cookies are cookies that we are in the process of classifying, together with the providers of individual cookies.
None
Powered by